Back to Beacon Group

Fully Automatic Hematology Analyzer

BONAVERA EXPRESS 5R

Overview
Bonvera Express 5R is an advanced 5-Part Differential Hematology Analyzer designed for CBC + 5 PDA, CBC + 5 PDA + Retic, and Body Fluid testing. It offers 35 reportable and 14 RUO parameters, high throughput of 90 samples/hour in CBC mode, 4-angle laser scattering technology for precision and economy, and a micro sample requirement of just 20 µL. With only 4 reagents plus 1 dye tube for Retic tests, 500,000-result storage, and eco-friendly sheath liquid usage, it’s ideal for reliable, efficient, and high-end hematology testing.
Download Brochure

    Hematology Analyzer with Facilities to Perform CBC + 5 PDA, CBC + 5 PDA + Retic Testing, 7 BF Parameters

    35 Reportable Parameter with 14 RUO Parameter

    Option to run single sample or use of Autoloader 

    Higher Linear Measurement Range

    Use of only 4 routine reagents and 1 separate Dye tube if want to perform Retic analysis, making it an ideal system to operate even low sample workload for Retic Testing

    Throughput of 90 sample in CBC Mode & 80 Sample in CBC + 5 PDA Mode

    4 Angle Laser Scattering technology that offers accuracy & precision together with economy  

    Longer shelf life of Reagent after opening

    Use of Sheath Liquid for 5 PDA analysis making it an environment friendly system

    Large Storage capacity of 5,00,000 Results with Data & Graphics

    Micro sample requirement of just 20 µl

    Principles

    WBC 5-part flow cytometry (FCM)+4 angles laser light scatter 
    WBC analysis: optical and impedance measurements 
    RBC/PLT analysis: impedance method 
    HGB test: cyanide-free reagent colorimetry 
    RETIC test: flow cytometry (FCM) + laser light scatter + chemical dye method 

    Parameters

    WBC, LYM%, MON%, NEU%, EOS%, BAS%, LYM#, MON#, NEU, EOS#, BAS#, RBC, HGB, HCT, MCV. 
    MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, PCT, P_LCR, PLCC, RETIC%, RETIC ABS, IRF 
    7 body-luid parameters: WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF# 
    14 research parameters: ALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#, BLAST%, BLAST#, InR%, InR#, 
    Eos-BF%, Eos-BF#, Neu-BF%, Neu-BF# 
    Blood routine provide: 3 histograms for WBC, RBC and PLT 
    2 scatter grams: 5-part differential scatter gram, eosinophils and neutrophils scatter gram 
    Two 3D stereograms 
    RETIC provides: 2 histograms, 2 scatter grams, two 30 stereograms 
    Body fluid provides: 2 histograms, 2 scatter grams, two 3D stereograms 

    Sample Modes

    Auto loader 20µL, manual mode 20µl, pre-diluted mode 20µl, body-fluid mode 70µl 

    Throughput

    CBC mode: 90T/H, CBC+5DIFF mode: 80T/H, Body-fluid mode: 30T/H 

    Aperture Diameter

    WBC 100µm, RBC/PLT 68µm 

    Sampling Device 

    Auto loader with 50 (10 x 5 racks) sample storage capacity | Built-in bar code reader (Optional) 

    Data Storage

    Up to 500,000 sample results with all data & graphics

Bonavera Express 5R is a new generation high-end Hematology analyzer providing 49 CBC parameters including 28 reportable CBC parameters with 5-part WBC differential, Reticulocyte enumeration, 7 Body Fluid parameters, and 14 RUO parameters.

It provides results for Retic_Abs count, Retic% and IRF.

Body fluid analysis helps diagnose various conditions by examining cell counts and characteristics in fluids like synovial, pleural, peritoneal, and pericardial fluids, aiding in detection of inflammation, infection, trauma, and malignancy.

It provides 7 Body Fluid parameters: Total Count-BF, WBC Count-BF, RBC Count-BF, Mononuclear Cells-BF (No & %), and Polymorphonuclear Cells-BF (No & %).

For Blood: Atypical Lymphocyte (ALY) # & %, Large Immature Cells (LIC) # & %, Nucleated RBC (NRBC) # & %, Blast Cells # & %, and Infected RBC (InR) # & %. For BF samples: Eosinophil-BF # & % and Neutrophil-BF # & %.

Yes, parameters InR# and InR‰ help detect malaria-infected red blood cells by indicating count and proportion of infected cells.

It offers 90 samples/hour in CBC mode and 80 samples/hour in CBC + 5 PDA mode.

Whole Blood Mode, Capillary Mode, and Prediluted Mode.

Minimum 20µl of sample is required.

Yes, it provides histograms, scattergrams, and stereograms for CBC, Reticulocyte, and Body Fluid analysis.

It can store up to 5,00,000 results including graphs and scattergrams.

It uses 4 routine reagents (Diluent, Lyse, Detergent, Sheath) and 1 maintenance reagent (Probe Cleaner). Reticulocyte counting requires an additional Retic prefilled tube.

Sheath reagent preserves WBC morphology for accurate optical scatter measurement and is dye-free, making it eco-friendly.

It uses Flow Cytometry with 4-angle laser scatter separation, offering more accurate WBC differentiation at economical cost.

It comes with a separate 17” color display allowing easy visualization of results, graphics, and flags on a single screen.

It supports single-sample operation with cap piercing and also includes an Autoloader for multiple samples.

The autoloader can process 50 samples at a time using 5 racks of 10 tubes each.

Yes, it supports LIS/HIS connectivity and follows HL7 protocol.
BONAVERA EXPRESS 5R